PORTABLE MESH NEBULIZER 10ML SRNZ802


#10635798
available for Indent

PORTABLE MESH NEBULIZER 10ML SRNZ802



15.7 % Rp 414,900

Rp 349,900

Benefits
  • Power Supply : D.C 3.7v Lithium Battery or DC 5V/1A
  • Power Consumption : <(><<)>2VA
  • Standby power consumption : <(><<)>0.02V A
  • Nebulization rate : >0.2mL/min
  • Particle Size(MMAD) : <(><<)>5μm
  • Medicine liquidCapacity : 8 mL
  • Types of nebulizeliquids : Solution and suspension
  • Minimum filling am ount of drug : 1 mL
  • Residual volume : <(><<)>0.5mL
  • Ultrasoni c Oscillation Frequency : 110KHz±10KHz
  • Respirable fraction performance : ≥60%
  • Noise level (dBA) : ≤50dBA
  • Time Auto-OFF : After Power on, continuous operation 20 minutes to auto-off
  • Operation environment : 10 -40°C, 10%-95%RH, 860-1060h Pa
  • Storage and Transportation environment : -20°C to 70° C, 10%-95% RH, 500-1060hPa
  • Dimension : 41 x 67 x 125 mm
  • Weig ht : 108g
Features
  • Power Supply : D.C 3.7v Lithium Battery or DC 5V/1A
  • Power Consumption : <(><<)>2VA
  • Standby power consumption : <(><<)>0.02V A
  • Nebulization rate : >0.2mL/min
  • Particle Size(MMAD) : <(><<)>5μm
  • Medicine liquidCapacity : 8 mL
  • Types of nebulizeliquids : Solution and suspension
  • Minimum filling am ount of drug : 1 mL
  • Residual volume : <(><<)>0.5mL
  • Ultrasoni c Oscillation Frequency : 110KHz±10KHz
  • Respirable fraction performance : ≥60%
  • Noise level (dBA) : ≤50dBA
  • Time Auto-OFF : After Power on, continuous operation 20 minutes to auto-off
  • Operation environment : 10 -40°C, 10%-95%RH, 860-1060h Pa
  • Storage and Transportation environment : -20°C to 70° C, 10%-95% RH, 500-1060hPa
  • Dimension : 41 x 67 x 125 mm
  • Weig ht : 108g
Specifications
  • Power Supply : D.C 3.7v Lithium Battery or DC 5V/1A
  • Power Consumption : <(><<)>2VA
  • Standby power consumption : <(><<)>0.02V A
  • Nebulization rate : >0.2mL/min
  • Particle Size(MMAD) : <(><<)>5μm
  • Medicine liquidCapacity : 8 mL
  • Types of nebulizeliquids : Solution and suspension
  • Minimum filling am ount of drug : 1 mL
  • Residual volume : <(><<)>0.5mL
  • Ultrasoni c Oscillation Frequency : 110KHz±10KHz
  • Respirable fraction performance : ≥60%
  • Noise level (dBA) : ≤50dBA
  • Time Auto-OFF : After Power on, continuous operation 20 minutes to auto-off
  • Operation environment : 10 -40°C, 10%-95%RH, 860-1060h Pa
  • Storage and Transportation environment : -20°C to 70° C, 10%-95% RH, 500-1060hPa
  • Dimension : 41 x 67 x 125 mm
  • Weig ht : 108g
Warranty Information

  • Warranty Part: 12 Month(s)
  • Services: 12 Month(s)