- Rule hardness: 40 HRc minimum.
- Flat depth gauge.
- Vernier with guide for better thumb position.
- Verni er endurance: 20 000 cyc les minimum.
- Vernier screw locking.
- Supplied in case with compliance certificate.
|
-
|
- Accuracy: 1/50th - 0.02 mm.
- A [mm] 200
- C [mm] 50
- E [mm ] 17
- L [mm] 290
- Bias error [µm] 30
- Accuracy [mm] 0,02 [ g] 419
|
|
-
|