A. Operation :

  1. Make sure B40 engine oil has been filled according to the height requirement of deep stick. Diesel fuel minimum of ½ tank is filled, water filled radiator coolant. Make sure hydraulic oil filled (special hydraulic system)
  2. Confirm batteries properly installed and ready to use
  3. Pump diesel fuel manually before the unit alive
  4. Make sure key starter installed and set up positions on, leave the unit alive for 5 minutes without load
  5. Turn on circuit braker (MCB), the main lights, and turn on each light one by one through the lights breaker
  6. To turn off the unit, perform the first step by turning off the lights and load one by one, then turn off the main MCB
  7. Let the unit alive for 5 minutes with no load, after it shut down, return the ignition key in off position
  8. Don't move the unit when it is still alive and the lights are switched on
  9. For the hydraulic type, make sure the four lamps really on, then upgraded the hydraulic

B. Usage :

  1. For transfer unit, do not pull with attached lamp position
  2. When move the unit, do not pull with a maximum speed of 40 km/h on flat road. To move off road must be very careful
  3. If the mast turned-on in the highest position, wind speed 20 km/h
  4. Do not use this unit more than 16 hours / day
  5. Do not touch bulb with bare hands (use gloves)
  6. Pause until the lights return to beginning temperature to turn on back (approximately 1-2 hours)
  7. Use type metal halide lamp 1500 watts
  8. Use types of diesel fuel, oil, and water radiator according to the instructions manual
  9. Put the unit in a protected and safe from the reach of strange objects
  10. Take maintenace with both periodic and appropriate time
  11. Confirm the flatness of generator when the unit is used.